FOR MORE INFORMATION PLEASE CALL US FOR OUR BROCHURE Email: sales@influxmeasurements.com Tel: +44 (0) 1962 736736 Fax: +44 (0) 1962 736737 |
© Influx Measurements Ltd |

Screwed or Flanged Connections High Visibility Scale Upgradeable Output Devices Independent 4 to 20 mA Output Hazardous Rating Customised Calibration High Working Pressures Repeatable Performance |

FloTrak meters are installed in vertical lines with flow upwards and are normally
supported by the pipework |
Gas Range Liquid Range Scale Length Alarms* Transmitter* Protection Accuracy Repeatability Temperature Pressure Flanged Screwed Sizes Materials |
0.1 - 1100 m³ / h (air equiv.) 5 L/h - 40 m³ /h (water equiv.) 100mm Single or Dual NAMUR Type (EEx ia IIC T6) 2 - wire 4 to 20mA (EEx ia IIC T6 or EEX nA II T6) IP65 ± 2% FSD 0.5% of Flow - 30° to + 65°C Ambient - 40° to + 200°C Fluid 100bar max. (or flange rating) DIN PN16 or ANSI 150 BSP female DN15-DN80 (¾" - 3") 316 SS standard |
Specification |
*Alarms and transmitter are optional |
FLOTRAK |